Canary Wharf development achieves record Passivhaus certification

Canary Wharf development achieves record Passivhaus certification

London’s tallest certified Passivhaus building incorporates three interconnected residential towers. The urbanest Canary Wharf development combines prefabricated façades, airtight construction, and heat recovery ventilation to meet stringent building energy performance requirements at high-rise scale.


IN Brief:

  • The development comprises towers of 46, 36, and 28 storeys.
  • Whole-building testing established an air permeability result of 0.62m³/(h·m²).
  • With a treated floor area of 45,171m², the development becomes Britain's largest Passivhaus-certified building.

urbanest has secured Passivhaus certification for its Canary Wharf development, establishing the world’s tallest fully certified Passivhaus building and the largest certified development for residential use.

The mixed-use scheme at 2 Trafalgar Way comprises three towers of 46, 36, and 28 storeys, providing 1,672 student bedrooms and 80 residential units alongside additional commercial and educational accommodation.

The development opened to residents in September 2026, following practical completion during the summer. Representatives of the project team received formal certification from the Passivhaus Institute on 24 November.

With a treated floor area of 45,171m², the development is almost twice the size of the previously largest certified Passivhaus building in Britain, the Woodmill and St Columba’s High Schools development in Dunfermline, which has a treated floor area of 23,151m².

Apt designed the Canary Wharf scheme, with Henriksen Studio undertaking Passivhaus design and façade engineering. Midgard, part of JRL Group, delivered construction.

The scale of the development required a building envelope capable of maintaining consistent thermal and airtightness performance across thousands of individual components and connections.

Its façade incorporates a bespoke unitised curtain wall system developed using WICONA’s aluminium façade and window technology. Manufacturing substantial façade assemblies away from the construction site allowed components to be integrated under controlled conditions before installation onto the permanent structure.

Unitised construction also reduced the volume of detailed assembly undertaken at height. However, the performance of the completed envelope remained dependent on connections between the prefabricated units, their supporting structure, and adjoining building components.

Structural fixings, floor slab interfaces, window surrounds, and connections between different façade elements can interrupt the continuity of insulation or airtightness layers.

Thermal bridges at these interfaces allow additional heat to pass through the building envelope, potentially increasing heating demand and reducing internal surface temperatures. Their treatment must therefore be considered alongside the thermal performance of the principal façade components.

The project incorporated aluminium system components manufactured using Hydro CIRCAL, which contains at least 75% recycled post-consumer aluminium scrap. Increasing the recycled content of these components addresses part of the façade’s embodied carbon profile separately from the operational performance requirements of Passivhaus.

Whole-building airtightness testing established an air permeability result of 0.62 cubic metres per hour per square metre of envelope area, according to WICONA.

The measurement describes air leakage relative to the surface area of the tested envelope. It differs from the air changes per hour measurement used to assess airtightness under Passivhaus certification, which relates leakage to internal air volume.

Achieving consistent airtightness in tall buildings requires consideration of pressure differences arising from both wind exposure and temperature variations between internal and external environments.

Temperature differences can generate stack effect, producing pressure variations between different levels of a building. Uncontrolled air movement through the envelope can consequently affect heating and cooling demand, alongside the distribution of internal airflows.

Reducing leakage allows ventilation to be managed more effectively through designed building services rather than relying on uncontrolled infiltration through the façade.

Mechanical ventilation with heat recovery transfers energy from extracted air to incoming fresh air, reducing the additional heating required during colder periods. The distribution and operation of these systems must account for the different occupancy conditions within bedrooms, communal areas, kitchens, and other accommodation.

High-density residential developments can experience considerable internal heat gains from occupants, electrical equipment, and domestic activities. Solar radiation through glazed elevations can add to those gains, making the assessment of overheating and cooling demand important alongside winter heating performance.

The project team’s coordination of façade engineering and building services design has enabled the development to satisfy the Passivhaus Institute’s certification requirements at a scale substantially larger than previously completed UK projects.

Certification establishes compliance with the applicable energy performance, comfort, and quality assurance criteria. Actual energy consumption will subsequently depend on the operation of installed systems, occupant behaviour, weather conditions, and maintenance.

The Canary Wharf scheme is urbanest’s second certified Passivhaus development, following completion of its Battersea student accommodation project in 2024. A further development at Albert Embankment is already progressing through the company’s Passivhaus construction programme.

Experience accumulated through the two completed schemes provides a foundation for subsequent work involving façade procurement, construction detailing, installation quality assurance, and whole-building performance testing.

With Canary Wharf now occupied, its operational performance will provide additional evidence of how these design and construction methods translate into energy consumption and indoor environmental conditions across a high-density residential development.



  • Canary Wharf development achieves record Passivhaus certification

    Canary Wharf development achieves record Passivhaus certification

    London’s tallest certified Passivhaus building incorporates three interconnected residential towers. The urbanest Canary Wharf development combines prefabricated façades, airtight construction, and heat recovery ventilation to meet stringent building energy performance requirements at high-rise scale.


  • Wynne begins £10m specialist training centre construction

    Wynne begins £10m specialist training centre construction

    Wynne Construction has started building a specialist Welsh training centre. The £10m development in Rhyl will expand practical education capacity for construction trades, low carbon building techniques, and automotive engineering.