IN Brief:
- Construction of the 4,000m² Builyeon Road primary school began on 23 November.
- The £25m works contract requires construction to Passivhaus Classic standard.
- The school will provide capacity for 420 primary pupils and 128 nursery children, supporting the expanding Queensferry community.
Morrison Construction has begun work on a £25m primary school and early learning centre in South Queensferry, delivering a building designed to meet Passivhaus Classic requirements for the City of Edinburgh Council.
Groundbreaking took place on 23 November at the Builyeon Road site, where the council is developing educational infrastructure to serve the surrounding community and the expanding Builyeon housing development.
The approximately 4,000m² building will provide 15 classrooms accommodating up to 420 primary pupils, alongside nursery provision for 128 children aged between two and five. The council expects the school to welcome its first pupils in August 2028.
Procurement documentation identifies Galliford Try Construction, trading as Morrison Construction, as the appointed contractor. The works contract was signed on 26 October at a value of £25,011,800 excluding VAT.
The contract specifies construction to Passivhaus Classic standard, alongside adherence to the principles of the Scottish Government’s Net Zero Public Sector Building Standard. Meeting those requirements places particular emphasis on the performance of the building envelope and the integration of its technical systems.
Passivhaus design combines high levels of thermal insulation, airtight construction, controlled ventilation, and consideration of solar and internal heat gains to reduce energy demand while maintaining comfortable indoor conditions.
Achieving the intended performance depends on maintaining continuity between individual building components. Insulation within external walls must connect effectively with roof and ground floor construction, while interfaces around windows, doors, and structural elements require detailing that limits unintended heat transfer.
Thermal bridges can increase heat loss and reduce internal surface temperatures. In a building containing numerous classrooms and associated communal spaces, repeated construction details provide opportunities to improve installation consistency, provided junctions are correctly designed and executed.
The Passivhaus airtightness criterion limits air leakage to 0.6 air changes per hour when tested at a pressure differential of 50 pascals. Meeting this requirement depends on the performance of the completed building envelope, rather than the nominal airtightness of individual products.
Penetrations through the envelope require coordination between architectural, structural, mechanical, and electrical designs. Ventilation ducts, electrical installations, drainage connections, and other services must pass through the relevant construction layers without compromising the continuity of the airtight barrier.
Intermediate testing during construction can help identify air leakage while critical junctions remain accessible. Once internal linings conceal those interfaces, identifying and correcting deficiencies can require additional work and disrupt subsequent construction activities.
Educational buildings also present particular ventilation requirements because occupancy levels vary significantly throughout the day. Classrooms can accommodate substantial numbers of pupils within relatively compact spaces, generating changing demands for fresh air and temperature control.
Mechanical ventilation with heat recovery is commonly used in Passivhaus buildings to reduce the amount of thermal energy lost when stale indoor air is replaced. The detailed system design must also account for acoustic requirements, filtration, fan energy consumption, and the ability to respond to changes in occupancy.
Managing overheating requires consideration of internal heat gains from pupils and equipment alongside solar radiation entering through the building envelope. Glazing specification, shading arrangements, and ventilation capacity can influence the ability to maintain acceptable indoor temperatures during warmer periods.
Morrison’s project-specific structural, heating, and ventilation specifications have not yet been disclosed in detail. Its contractual Passivhaus requirement nevertheless establishes measurable performance criteria against which the completed building can be assessed.
The school forms part of a wider development area identified through Edinburgh’s planning framework, where land has been allocated for housing and associated community infrastructure. Planning documentation also identifies provision for a bus stop outside the school, connecting the development with wider Queensferry and Dalmeny railway station.
Delivering the school alongside residential development requires coordination between building construction, permanent access arrangements, and supporting transport infrastructure. The opening programme must accommodate the completion of facilities required for safe access by pupils, staff, and other building users.
Combining primary education and nursery accommodation within a single building also creates opportunities to coordinate shared services while maintaining spaces suited to different age groups. The respective facilities may operate according to different occupancy patterns, requiring appropriate configuration of environmental controls and internal circulation.
Construction will progress towards completion ahead of the planned August 2028 opening. Building performance testing, commissioning, and Passivhaus certification will provide subsequent measures of whether the completed facility meets the energy and environmental requirements established in the works contract.