Jefferson expands infrared heating range for sites

Jefferson expands infrared heating range for sites

Jefferson Tools has expanded its infrared heating range for sites. A 15kW fuel-burning unit joins two electric 2.4kW cabinet heaters, with different ventilation and electrical supply requirements for construction and workshop applications.


IN Brief:

  • Jefferson's Infrared 51 uses diesel or kerosene to deliver a stated 15kW thermal output for ventilated work areas.
  • Two electric cabinet variants contain paired 1.2kW halogen elements and are offered in 110V and 230V configurations.
  • The 110V cabinet model requires a 32A supply, while the fuel-burning unit requires ventilation and combustion-risk assessment.

Jefferson Tools has expanded its infrared heater range with one 15kW diesel or kerosene model and two 2.4kW electric cabinet units, offering different equipment for ventilated workshops and temporary site spaces. The distinction between combustion heat and electric radiant heat affects ventilation, electrical loading and fire precautions, so the models should not be treated as interchangeable merely because they use infrared radiation.

The new Infrared 51 is rated at 51,000 BTU per hour, equivalent to approximately 15kW of thermal output. It burns diesel or kerosene and is intended for well-ventilated applications. The manufacturer gives an indicative heating capacity of 350 cubic metres, but that figure should not be treated as a guaranteed room temperature or a substitute for an assessment of heat losses, air movement and safe ventilation.

Infrared heating transfers energy directly to exposed people and surfaces in its line of sight, rather than relying entirely on warming and circulating the air in a workspace. In a draughty workshop this can provide localised heat, but any obstruction reduces its reach and adjacent materials may be exposed to high surface temperatures. Positioning, clearance and the intended use of the area therefore influence the selection and siting of each unit.

The Infrared 51 has an 11-litre fuel tank and a manufacturer-stated consumption of 1.5 litres per hour. Jefferson specifies a maximum runtime of six hours, which should be used rather than assuming that dividing nominal tank capacity by the quoted rate will always predict operating time. Its associated electrical demand is 65W at 230V, used for controls and related functions, and must not be confused with the 15kW thermal rating produced by combustion.

The manufacturer identifies an LED thermostat, overheat cut-out, tip-over protection and a floor deflector on the Infrared 51. A timed cooling arrangement is also specified for the combustion chamber after shutdown. These are safeguards built into the appliance; they do not replace assessment of ventilation, fuel handling, carbon monoxide exposure or the proximity of flammable materials in the particular work area.

The two cabinet models instead use ruby halogen electric elements, each rated at 1,200W, arranged in a reflector housing for directional heating. Both provide selectable 1.2kW or 2.4kW output and thermostatic operation, according to the manufacturer. The 110V version is marketed for site use, while a separate 230V version serves compatible work areas. Their infrared radiation can deliver prompt warmth at the point of use, but total energy consumption at full rated output remains 2.4kW.

The manufacturer specifies a 32A input for the 110V cabinet heater. The stated nominal heating load is 2.4kW, but an available 110V socket is not necessarily suitable: plug and distribution equipment, transformer capacity, cable routing and circuit loading must all match the appliance requirements. Other tools and welfare equipment may already be drawing from the same temporary site electrical system, which makes a dedicated supply assessment important.

HSE construction guidance generally favours cordless or reduced-voltage electrical equipment where suitable and warns about damage to portable plugs and cables in building-site conditions. When 230V equipment is used, the electrical installation and protection arrangements require particular attention. Heaters introduce an additional fire risk because they can expose nearby combustible materials to high temperatures, including packaging, timber, insulation and temporary protection sheets commonly found around construction work.

Direct combustion heaters introduce a different hazard. Carbon monoxide can form when carbon-based fuel burns incompletely, while any unflued combustion appliance also needs an adequate source of fresh air and control of emissions. HSE construction guidance highlights the danger of fuel-powered equipment in enclosed or poorly ventilated places. Jefferson specifies the Infrared 51 for well-ventilated areas, not as a universal solution for sealed rooms or confined workspaces.

Electric cabinet heaters avoid combustion exhaust at the point of use, but exposed elements and hot surfaces still require safe separation from temporary protection, insulation, packaging and other combustible material. Jefferson lists an IP20 ingress protection rating for the 110V model; that rating provides no protection against water ingress. The cabinet is consequently not presented as a weatherproof outdoor heater simply because it uses the reduced voltage common on construction sites.

The Infrared 51 and the cabinet models are intended for different heating conditions. The fuel unit offers higher nominal thermal output but needs combustion controls and suitable ventilation, while the electric versions require adequate supply capacity and appropriate protection from site conditions. Manufacturer specifications establish their ratings and features; independent comparative heating performance and operating cost measurements were not available in the launch information.